Minimum rebar dia for sunken slab shall be not less than 10mm. Waterproofing compound is to be added in concrete mix and rendering(Plastering) must be done on the same day itself by Providing adequate slope towards outlet corner.
*space between the normal floor level and sunken slab is filled with sand, broken pieces of bricks or other lightweight materials to protect the pipes and reduce maintenance.*
siraj siyad
Contractor | Alappuzha
20cm kooduthal debth paadilla
N UNNIKRISHNAN NAIR
Civil Engineer | Alappuzha
Minimum rebar dia for sunken slab shall be not less than 10mm. Waterproofing compound is to be added in concrete mix and rendering(Plastering) must be done on the same day itself by Providing adequate slope towards outlet corner.
Sumesh STYLE HOUSE BUILDERS
Civil Engineer | Thiruvananthapuram
maintain the proper depth and compulsory provide water proofing
Tinu J
Civil Engineer | Ernakulam
*space between the normal floor level and sunken slab is filled with sand, broken pieces of bricks or other lightweight materials to protect the pipes and reduce maintenance.*