hamburger
Fousiya Kabeer

Fousiya Kabeer

Home Owner | Kozhikode, Kerala

ബീമിന്റെ ഡെപ്ത് എന്ത് അനുസരിച്ചു ആണ് നിശ്ചയിക്കുന്നത്? ?
likes
0
comments
5

Comments


Structure Lab
Structure Lab

Civil Engineer | Kozhikode

Roughly you can give span/10 subject to a minimum of 30cm including slab. You will get a more economic Size if u consult a structural Engineer.

Mariyamma M S
Mariyamma M S

Civil Engineer | Thiruvananthapuram

beam depth depends on the span and load on the beam. also follow the rules of span to depth ratio as per IS 456.

N UNNIKRISHNAN NAIR
N UNNIKRISHNAN NAIR

Civil Engineer | Alappuzha

Span depth ratio as Per IS 456-2000 is L/26 for Fixed / Continuous beams up to 10.00 m Span. Anticipated loads on floor and beam including its self weight also considered for fixing the effective depth .

Aashi aashik
Aashi aashik

Contractor | Malappuram

steel work

Abdul Rahim
Abdul Rahim

Civil Engineer | Thiruvananthapuram

structural design contact cheyu