hamburger
A FRAME Developers

A FRAME Developers

Civil Engineer | Thiruvananthapuram, Kerala

Rebar detection system - Many consultancies do wrong practice for conducting NDT(Non destructive test) for concrete . They simply select Random point As per revised IS code Before conducting NDT We have to ensure whether the test conducting Area should be free from reinforcement bars ( If not wrong result may get).Rebar detection system helps to locate rebars in concrete section. Then we do UPV (ultra sonic pulse velocity test) to ensure homogeneity of concrete in that particular area to which test is conducted . After only that we do Rebound hammer test (NDT) Note: Ultrasonic pulse velocity test for concrete is IS 516 (Part-5 Sec-1) : 2018. The old IS code for the UPV test is IS 13311 Part-1 Rebond hammer- IS 516 (PART-5 Sec-4) #StructureEngineer #KeralaStyleHouse #StrengthMatters #magicStructure #HouseDesigns #Designs #koloed #kolo-ed #koloapp #kolopost
likes
2
comments
0

kolo background graphic

Join the Community to
start finding Ideas &
Professionals

Get it on Google PlayGet it on App Store