Smart Select
Projects
Masterclass
Quiz
Smart Select
Masterclass
Quiz
For Homeowners
For Professionals
Ramees Ali
Architect | Malappuram, Kerala
Building on a sloping contour site requires more than design, it demands precise structural thinking. A home carefully engineered for the terrain in the Nilgiris. #hillarchitecture #nilgiris #radarchitecture #structuralengineering #rameesali
2
0
More like this
Focien
Civil Engineer
The foundation is being established on a large, uneven rock formation. This requires careful excavation into the soil surrounding the rock and precise planning for the footings to ensure a stable and level base, which is far more demanding than working on uniform, level ground. #experienced #precisecraftsmanship #timelycompletion #houseinkerala #KeralaStyleHouse #Focien
the malluengineer
Civil Engineer
Check description ⬇️👇 comment your thoughts In these situations go for safety rather than the cost. Covers are given to provide protection against corrosion and fire to the rebars. If less cover is provided, protection against the above will be inadequate. And if more than required is provided then the concrete on the tension side of any structural member, will crack under tension. Cover is provided to increase the structural integrity and coherence of the concrete in cover region. Concrete covering is provided in every element of the building (Slabs, Beams, Columns Footings) wherever the reinforcement is used. For a longitudinal reinforcing bar in a column, a concrete cover not less than 40 mm not less than the diameter of such a bar should be provided. In the case of columns of the minimum dimension of 20 cm or under, whose reinforcing bars do not exceed 12 mm, the concrete cover of 25 mm is to be used for reinforcement. 4 more follow @themalluengineer #columndesign #structure
the malluengineer
Civil Engineer
Comment your experience. Like and follow and support pls🤍 Share with needful people. "Prevention is better than cure" These cracks are mainly due to the expansion of concrete due to rusting of reinforcement inside this can be reduced by proper supervision and by taking prevention measures. It should be repaired in the beginning stage itself if it is showing hair line cracks of thickness more than 5mm in size. Repair procedure 1. Remove existing plastering and check the reinforcement. 2. Remove the rust with a wire brush. 3. Apply a protection coat. 4. Replaster using pins and fibre mesh. 5. Give a waterproofing protection above it. This will give a long life to structure. Build better. Protect your dream. If you notice these kinds of issues it is better to consult a professionally qualified engineer near you
Kolo
Kerala
Architect
Ramees Ali
1630011373
Join the Community to
start finding Ideas &
Professionals