hamburger
Saneesh Unnikrishnan

Saneesh Unnikrishnan

Home Owner | Thrissur, Kerala

Lintelinte hight ethra venam? Cement,M Sand , Metal ratio? Iron Bar reccommended size ? ithu oru 1700 square feet thazheyum,1300 square feet meleyum ulla veedanu. Ningalude vilappetta advise pratheekshikkunnu. ๐Ÿ™
likes
10
comments
7

Comments


Vikas TP
Vikas TP

Civil Engineer | Kozhikode

minimum garde of concrete for rcc work is m 20. เด…เดคเดพเดฏเดคเต 1:1.5:3 mix. เดชเดฟเดจเตเดจเต† lintel size 20X20 เด•เตŠเดŸเตเดคเตเดคเดพเตฝ เดจเดจเตเดจเดพเดฏเดฟเดฐเดฟเด•เตเด•เตเด‚. เดฑเต‹เดกเตเดธเต 8mm 4nos and 8mm stirrups 20cm c/c koduthal madhiyakum.

Shan Tirur
Shan Tirur

Civil Engineer | Malappuram

plan เด†เดฏเดคเต เด†เดฃเต‹?

Abdul Rahiman Rawther
Abdul Rahiman Rawther

Civil Engineer | Kottayam

can decide on seeing plan for reinforcement

Mohamed  Sajid
Mohamed Sajid

Civil Engineer | Malappuram

Plan undo, 1:2:4 mathi mix ratio, #4 nos 8mm dia bar, ring 8mm at 20mm c/c, beam ulla sthalath maattam varum (minimum span ullel bottom 16mm, top 12mm)

Aashi aashik
Aashi aashik

Contractor | Malappuram

plan varachittundo ?

ARJUN CM
ARJUN CM

Contractor | Thrissur

lintel height 15 cm width same as wall thickness 12 mm dia and 16 mm dia bars use cheyyam

Sukumar mandal
Sukumar mandal

Home Owner | Alappuzha

labour and manpower supplies agar kisi Ko labour ki jarurat hoga to call Karen 81673.49340

More like this


kolo background graphic

Join the Community to
start finding Ideas &
Professionals

Get it on Google PlayGet it on App Store